V-BMS SWITCH MODULE
Up To 100V & up to 200A
V-BMS Switch module monitors battery current with built-in shunt resistor and controls connection to the charger & load over 2 separate paths via internal MOSFET’s. It also serves as a master module for the battery management system; sharing & gathering data to/from slave modules and evaluating warnings & alarms.
- Supports up to 50 BMS Modules & up to 16 parallel strings
- Fully programmable CANBus interface & charger control functions
- Fully plug & play; detects connected modules, number of cells, number of sensors, number of strings and string shunts
- Configurable Modbus port for monitoring & controlling the system
- All module configuration can be managed using cross-platform V-BMS software.

TECHNICAL DATA
| Parameters | Comments | Minimum | Typical | Maximum | Unit |
| Supply Voltage | Model 40V200 | 9 | - | 40 | V |
| Model 60V150 | 12 | - | 60 | ||
| Model 80V120 | 18 | - | 80 | ||
| Model 100V100 | 24 | - | 100 | ||
| Battery Voltage | Model 40V200 | 0 | - | 40 | V |
| Model 60V150 | 0 | - | 60 | ||
| Model 80V120 | 0 | - | 80 | ||
| Model 100V100 | 0 | - | 100 | ||
| Continuous Battery Current | Model 40V200 | -200 | - | 200 | A |
| Model 60V150 | -150 | - | 150 | ||
| Model 80V120 | -120 | - | 120 | ||
| Model 100V100 | -100 | - | 100 | ||
| Peak Battery Current | Model 40V200 | -300 | - | 300 | A |
| Model 60V150 | -220 | - | 200 | ||
| Model 80V120 | -180 | - | 180 | ||
| Model 100V100 | -150 | - | 150 | ||
| Current Mesurement Resolution | - | - | 12 | bits | |
| Current Measurement Error | -1 | - | +1 | % | |
| Charge port precharge time | With possibly additional Vds time | 1 | - | 30 | Seconds |
| Charge port hiccup Time | 1 | - | 30 | Seconds | |
| Load port precharge time | With possibly additional Vds time | 1 | - | 30 | Seconds |
| Load port hiccup time | 1 | - | 30 | Seconds | |
| Precharge current | 10 | A | |||
| MODBus baudrate | 9600 | - | 115200 | Bps | |
| CANBus baudrate | 125 | - | 1000 | Kbit/sec | |
| Number of CANBus messages | - | - | 8 | - | |
| Sleep Mode Power Consumption | - | 100 | - | mW | |
| Operational Power Consumption | - | 2 | - | W | |
| Operational Temperature Range | -40 | - | +50 | °C | |
| Humidity Level | 0 | - | 95 | %Rh | |
| Altitude | 6000 | m | |||
| Weight | Including Case | 650 | gr | ||
| Functional Features | Battery current measurement using internal shunt | ||||
| Uni-directionally switched CHARGE & LOAD port (allows regenerative currents to LOAD port, slow discharge over CHARGE port) | |||||
| Automatic module addressing, serial cell / parallel string detection (up to 50 modules / up to 16 parallel strings) | |||||
| Automatic module detection, hard power control for slave modules | |||||
| Fully programmable CANBus baudrate (125/250/500/1000 kbit/sec) | |||||
| Up to 4 CANBus information/control message with programmable period, length and 16 bit fields | |||||
| CANBus Charger Start/Stop/Pause/Resume messages with programmable length and 16 bit fields | |||||
| Available CANBus fields; Battery voltage, Battery Current, Max. Charging Voltage, Max. Charging Current, Charging Current Percentage, Minimum Cell Voltage, Maximum Cell Voltage, Minimum Cell Temperature, Maximum Cell Temperature | |||||
| Selectable scale / programmable offset for battery/charging voltage, battery/charging current, percentage fields | |||||
| Charger Detection over CANBus | |||||
| Configurable MODBus port; 9600/19200/38400/57600/115200 bps, 8 data bits, 2 Stop bits or Odd/Even Parity with 1 Stop bit | |||||
| Supported MODBus commands; Read Input Registers, Read Holding Registers, Write Single/Multiple Registers | |||||
| Password protection for Holding (Configuration) Registers | |||||
| Fully configurable over MODBus slave port | |||||
| Periodic data sharing/gathering to/from slave modules, warning & alarm control, balancing control | |||||
| Port control with single function button | |||||
| Safety Features | Programmable load current warning & alarm levels | ||||
| Programmable charge current warning & alarm levels | |||||
| Module high temperature protection | |||||
| Communication timeout/error protection | |||||
| ALARM output for critical errors | |||||